Zibo xiangrun and Shandong Bairui manufacture all kinds of Alumina adsorbent . XR alumina adsorbent could costly reduce your cost and time. With different promotor, alumina adsorbent could adsorb different waste gas in the oil and petrochemical system.
When activated alumina place a certain time or use some time, and it is no longer effective and must be regenerated. The regeneration temperature is 170-230°C. The actual temperature is set by the design of the unit.
The bed outlet temperature should always be lower than the inlet during heating. If the outlet temperature increase higher than the inlet, so please stop the heating immediately. It indicates that a heat-releasing reaction may be occurring. Close the inlet and outlet valves to the vessel being heated, depressurize it to the flare, and purge it with nitrogen.
During regeneration, the alumina bed may be as hot as 260°C. Always check the temperature in the cooling outlet after regeneration to ensure the bed is cool before exposing it to the feed stream. The adsorbent has high heat capacity and low thermal conductivity. It can stay hot for weeks if a shutdown occurs before the bed has been completely cooled. For systems with automatic switching, always check following a shutdown to ensure that a hot bed is not switched from cooling prematurely.
Type |
Plastic bag |
Drum |
Drum |
Super sack/Jumbo bag |
Bead |
25kg/55lb |
25 kg/ 55 lb |
150 kg/ 330 lb |
750kg/1650lb 900kg/1980lb 1000kg/ 2200 lb |